| > Typical
Module Efficiency | > Typical
Applications | > Material
Specifications

Why
Choose POREX® Tubular Membrane Module
- POREX® Filtration
Modules provide consistent, reliable solid/liquid
separations and long service life
- Sintered
PE substrate with PVDF membrane offers high-performance
tubular membrane with
superior operating characteristics
- Sintered
PVDF substrate with PVDF membrane offers high temperature
and improved chemical
compatibility (pH range of 0–14 standard units)
- PVDF/PVDF
composite option offers increased abrasion resistance
- Three
distinct membrane pore sizes available on two different
substrate options
- Uniform,
thermally-bonded omni-directional substrate pore
structure provides an optimized
support structure for tubular membranes
- Two
internal tube diameters available to suit your
application’s
flux and solids level requirements
(up to 5% by weight)

Typical
Module
Efficiency:
Module
flux may vary by application and solids concentration.
Performance in specific fluids need to be individually
verified. Typical performance of a 6 ft, 10 tube module,
with 0.1 micron nominal PVDF membrane on PE substrate
processing a FeCl3 / NaOH wastewater stream with NTU >500.
Permeate quality delivered was <0.5 NTU.


Typical
Applications:
- Heavy
metal removal in metal finishing fluids
- Pre-reverse
osmosis filters for water treatment
- High
solids removal in electroplating solution baths
- High
solids removal from completion fluids
- Food
and beverage processing
- Cutting
fluids recycling in silica grinding and slicing
- Heavy
metal removal from incinerator scrubber water
- Cooling
tower blow-down recycling and/or side stream filtration
- Brine
recycling in water treatment systems
- Wastewater
processing from the chemical,
micro-electronics and pulp and paper industries


Material
Specifications :
| Substrate
Tube |
Polyvinylidene
Fluoride, Polyethylene |
| Membrane |
Polyvinylidene
Fluoride |
| Nominal
Membrane Pore Size (μm) |
0.5,
0.1, 0.05 (MM type) |
Nominal
Sinter Tube (MS Type)
Pore Size (μm) |
20
(FIN), 100 (COR) |
| Maximum
Differential Pressure (PSI) |
60
(1 inch tubes), 120 (1/2 inch tubes) |
| Housing
Material |
PVC,
CPVC |
Housing
Connections
(10 x 1 inch tube) |
Length – 72
inches
Diameter – 6 inches
End Connections – 6 inch OD Victaulic groove
Permeate Ports – 3 inch
OD Victaulic groove
Sample Port – ¼ inch NPT plug |
Housing
Connections
(4 x 1 inch tube) |
Length – 72
inches
Diameter – 6 inches
End Connections – 4 inch OD Victaulic groove
Permeate Ports – 1 inch OD Victaulic groove
Sample Port – ¼ inch NPT plug |
Housing
Connections
(42 x 1/2 inch tube) |
Length – 72
inches
Diameter – 8 inches
End Connections – 8 inch OD Victaulic groove
Permeate Ports – 3 inch OD Victaulic groove
Sample Port – ¼ inch NPT plug |

|