POREX® Radial Cartridge Filter

Radial Cartridge Flow Summary

Test Method: Clean Water Permeability
Fluid: Water
Temperature: Ambient
Sample: CRE005 - 5 Micron Radial Cartridge

2.65" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE00512NNNN 6.8 5.44 5.0
CRE00512NNNN 6.8
CRE00512NNNN 3.4
CRE00512NNNN 4.25
CRE00512NNNN 5.7
CRE00512NNNN 5.7

4.5" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE00564NNNN 9.26 9.07 8.3
CRE00564NNNN 8.70
CRE00564NNNN 9.42
CRE00564NNNN 8.93
CRE00564NNNN 8.93
CRE00564NNNN 9.17

6.1" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE00566NNNN 19.23 18.69 18.0
CRE00566NNNN 19.80
CRE00566NNNN 17.70
CRE00566NNNN 18.52
CRE00566NNNN 18.87
CRE00566NNNN 19.61


Test Method: Clean Water Permeability
Fluid: Water
Temperature: Ambient
Sample: CRE010 - 10 Micron Radial Cartridge

2.65" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE01062ANBN 9.4 9.33 8.0
CRE01062ANBN 10.15
CRE01062ANBN 9.3
CRE01062ANBN 8.7
CRE01062ANBN 9.15
CRE01062ANBN 9.27

4.5" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE01064NNNN 12.20 12.04 10.1
CRE01064NNNN 12.50
CRE01064NNNN 12.82
CRE01064NNNN 12.05
CRE01064NNNN 12.50
CRE01064NNNN 10.20

6.1" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE01066NNNN 42.86 39.08 30.0
CRE01066NNNN 42.86
CRE01066NNNN 40.54
CRE01066NNNN 42.86
CRE01066NNNN 36.59
CRE01066NNNN 36.59
CRE01066NNNN 31.25


Test Method: Clean Water Permeability
Fluid: Water
Temperature: Ambient
Sample: CRE020 - 20 Micron Radial Cartridge

2.65" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE02062ANBN 15 13.73 11.5
CRE02062ANBN 17.65
CRE02062ANBN 17.8
CRE02062ANBN 11.33
CRE02062ANBN 11.33
CRE02062ANBN 9.27

4.5" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE02064NNNN 15.00 16.44 15
CRE02064NNNN 16.48
CRE02064NNNN 17.86
CRE02064NNNN 16.48
CRE02064NNNN 16.13
CRE02064NNNN 16.67

6.1" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE02066NNNN 93.75 16.44 15
CRE02066NNNN 115.38
CRE02066NNNN 115.38
CRE02066NNNN 136.36
CRE02066NNNN 136.36
CRE02066NNNN 125.00
CRE02066NNNN 103.18

* Calculated Value. Beyond pump capcity. Core limitation will alter value.

Test Method: Clean Water Permeability
Fluid: Water
Temperature: Ambient
Sample: CRE050 - 50 Micron Radial Cartridge

2.65" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE05062ANBN 13.2 30.93 >22
CRE05062ANBN 30.4
CRE05062ANBN 21.2
CRE05062ANBN 30.60
CRE05062ANBN 31.20
CRE05062ANBN 31.00

4.5" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE05064NNNN 18.07 18.85 18.0
CRE05064NNNN 17.05
CRE05064NNNN 19.74
CRE05064NNNN 18.75
CRE05064NNNN 19.48
CRE05064NNNN 20.00

6.1" Radial Cartridge
  Flow rate @ 1 psid
Cartridge ID Flow Rate Average Published
CRE05066NNNN 214.29 206.63* >50
CRE05066NNNN 214.29
CRE05066NNNN 214.29
CRE05066NNNN 187.50
CRE05066NNNN 187.50
CRE05066NNNN 214.29
CRE05066NNNN 214.29

* Calculated Value. Beyond pump capcity. Core limitation will alter value.